Netconf monitoring RFC 6022 Sessions (https://github.com/clicon/clixon/issues/370)

- statistics and transport/source-host parameters
  - extended internal NETCONF hello with transport and source-host attributes
clixon-lib,yang
  - Moved all extended internal NETCONF attributes to the clicon-lib namespace
C-API:
  - wrapped most attribute creation into new fn xml_add_attr()
This commit is contained in:
Olof hagsand 2023-01-14 11:25:39 +01:00
parent 7558d40faa
commit 3916fa919c
36 changed files with 883 additions and 402 deletions

32
apps/snmp/README.md Normal file
View file

@ -0,0 +1,32 @@
SNMP
====
The SNMP frontend acts as an intermediate daemon between the Net-SNMP
daemon (snmpd) and the Clixon backend. Clixon-snmp communicates over the AgentX
protocol to snmpd typically via a UNIX socket, and over the internal IPC protocol to the Clixon
backend.
Use Net-SNMP version 5.9 or later
To set up AgentX communication between ``clixon_snmp`` and ``snmpd`` a
Unix or TCP socket is configured. This socket is also configured in
Clixon (see below). An example `/etc/snmpd/snmpd.conf` is as follows::
master agentx
agentaddress 127.0.0.1,[::1]
rwcommunity public localhost
agentXSocket unix:/var/run/snmp.sock
agentxperms 777 777
It is necessary to ensure snmpd does `not` to load modules
implemented by Clixon. For example, if Clixon implements the IF-MIB and
system MIBs, snmpd should not load those modules. This can be done
using the "-I" flag and prepending a "-" before each module::
-I -ifTable -I -system_mib -I -sysORTable
Net-snmp must be started via systemd or some other external mechanism before clixon_snmp is started.
To build the snmp support, netsnmp is enabled at configure time. Two configure options are added for SNMP:
* ``--enable-netsnmp`` Enable SNMP support.
* ``--with-mib-generated-yang-dir`` For tests: Directory of generated YANG specs (default: $prefix/share/mibyang)